Focal length measurement of microlens-array by the clarity function of digital image

机译:微透镜阵列的焦距测量数字图像的清晰度函数

获取原文

摘要

In this paper, a method for the focal length measurement of Microlens-array (MLA) is introduced. The measuring setup is composed by monochromatic, condenser, collimator, MLA, microscope and CCD sensor. An experiment was performed using a MLA whose focal length is about 8 mm and a GUI based on Matlab software was developed to analyze the image gathered at the vertex and the focus by the clarity of digital image processing technology. The measuring uncertainty of this method is about 0.8% and this method introduced in this paper can finish tens of microlens array measurement at a single shot. Compared with traditional technology for MLA measuring, this method not only has a preferable precision but also super efficiency.
机译:本文介绍了一种用于微透镜阵列(MLA)的焦距测量方法。测量设置由单色,冷凝器,准直器,MLA,显微镜和CCD传感器组成。使用MLA进行实验,其焦距为约8mm,并且开发了基于MATLAB软件的GUI,以分析在顶点上聚集的图像,并通过数字图像处理技术的清楚起见。该方法的测量不确定度约为0.8%,本文介绍的该方法可以在单次拍摄时完成几十微液阵列测量。与MLA测量的传统技术相比,这种方法不仅具有优选的精度,而且还具有超级效率。