首页> 外文会议>Air Waste Management Association's annual conference exhibition >Measurements of fugitive emissions of a biogas production plant in Germany with op-FTIR and conventional measurement systems
【24h】

Measurements of fugitive emissions of a biogas production plant in Germany with op-FTIR and conventional measurement systems

机译:用OP-FTIR和常规测量系统测量德国沼气生产厂的逃放排放

获取原文

摘要

In this study open path optical measurement systems have been used together with conventional measurement equipment to find potential leakages of a biogas production plant. For the open path optical measurements two op-FTIR systems and a tunable diode laser (TDL) system have been used. The conventional system used in this study was a FID/PID waste gas monitor. Methane, produced by the biogas production process, was the key compound used for the leakage measurements. The results of the measurements showed, that an exhaust valve was the main emission source for the methane emissions and that the fermenter tanks of the plant and the substrate silos were not the main emission sources.
机译:在该研究中,开放路径光学测量系统已与传统的测量设备一起使用,以找到沼气生产植物的潜在泄漏。对于开放路径光学测量,已经使用了两个OP-FTIR系统和可调谐二极管激光器(TDL)系统。本研究中使用的传统系统是FID / PID废气监测器。由沼气生产过程产生的甲烷是用于泄漏测量的关键化合物。测量结果表明,排气阀是甲烷排放的主要发射源,植物的发酵罐和衬底筒仓不是主要发射源。