This paper deals with the investigation results of upcoated fibers with 500 mu m OD with regard to their temperature behaviour. All tests are based on graded index 50 mu m core Multimode fibers (fiber type Ala according to IEC 60793-2-10). The purpose of this study was to find out, how different design and material options influence the attenuation of a 500 mu m fiber within a temperature range of -60 deg C to +140 deg C. The results reveal the option to limit the maximum attenuation increase to approximately 0.01dB/km at 1300nm wavelength versus the whole temperature range. Choosing a well adapted upcoating material with a wide Glass Transition Temperature Range or using a thin sliding layer between the original coating and the fiber jacket achieves the desired results.
机译:本文对其温度行为进行了500亩,覆盖纤维的调查结果。所有测试都基于分级指数50μm核心多模纤维(根据IEC 60793-2-10的光纤型ALA)。本研究的目的是找出,不同的设计和材料选择如何影响到-60℃至+140℃的温度范围内500 mu m纤维的衰减。结果显示了限制最大衰减的选项在1300nm波长与整个温度范围内增加到约0.01dB / km。选择具有宽玻璃化转变温度范围或使用原始涂层和纤维夹套之间的薄滑动层的适应性覆盖材料,实现了所需的结果。