首页> 外文会议>International Conference on Indoor Air Quality and Climate >CORRELATION BETWEEN AIR TIGHTNESS AND AIR QUALITY IN MONGOLIAN HOUSES
【24h】

CORRELATION BETWEEN AIR TIGHTNESS AND AIR QUALITY IN MONGOLIAN HOUSES

机译:蒙古房屋气密性与空气质量的相关性

获取原文

摘要

A wide range of indoor winter pollutant concentrations (0.42-22 ppm carbon monoxide, 0.06-2.3 ppm sulphur dioxide, and 0-7 mg/m3 PM10) were measured in households in the suburban "ger" districts of Ulaanbaatar, Mongolia. These houses are heated with coal and wood in vented, poorly sealed stoves situated in living spaces. Blower door testing results showed poor air sealing (9 to 50 air changes per hour at 50 Pa) relative to houses in other cold climates. The air fightness is strongly correlated with household ventilation because air infiltration is the only reliable mechanism for ventilation. No correlation was found between the measured pollutant concentrations and air tightness. It is suspected that outdoor pollutant concentrations and indoor stove emissions control the levels of indoor pollutants. It was recommended that greater understanding of the nature of the pollutant sources and sinks is necessary for guiding future mitigation efforts.
机译:在郊区“GER”区蒙古郊区“GER”地区的家庭中,测量了各种室内冬季污染物浓度(0.42-22ppm一氧化碳,0.06-2.3ppm二氧化硫和0-7mg / m3 pm10)。这些房屋用煤炭和木材加热,位于生活空间的通风,密封的炉灶中。鼓风机门测试结果显示空气密封差(在50 pa的每小时9至50空气变化)相对于其他寒冷气候中的房屋。空袭与家庭通风强烈相关,因为空气渗透是通风的唯一可靠机制。在测量的污染物浓度和空气密封性之间没有发现相关性。怀疑户外污染物浓度和室内炉排控制室内污染物的水平。建议更多地了解污染物源和汇款的性质,是指导未来缓解努力所必需的。