首页> 外文会议>IEEE International Power Electronics Congress >Transient response comparison of conventional and output- inductorless two-stage DC-DC converter with low-voltage/high-current output
【24h】

Transient response comparison of conventional and output- inductorless two-stage DC-DC converter with low-voltage/high-current output

机译:低压/高电流输出传统输出电气两级DC-DC转换器的瞬态响应比较

获取原文

摘要

This paper presents the improvement of the transient response and stability for a two-stage DC-DC converter by removing the output inductor. The conventional two-stage converter consists of a buck converter used as the first stage and a half-bridge converter used as the second stage. The proposed circuit topology removing the output inductor and the conventional topology are compared. Removing the output inductor results in the system-order reduction of the transfer function. As a result, the stability is improved, and the crossover frequency of the open-loop transfer function becomes higher. The effectiveness of the proposed circuit topology was experimentally confirmed.
机译:本文通过移除输出电感器来提高两级DC-DC转换器的瞬态响应和稳定性。传统的两级转换器包括用于第一级的降压转换器和用作第二级的半桥转换器。比较了去除输出电感和传统拓扑的所提出的电路拓扑。删除输出电感导致传递函数的系统顺序减少。结果,稳定性得到改善,并且开环传递函数的交叉频率变高。实验证实了所提出的电路拓扑的有效性。