首页> 外文会议>International Conference on Greenhouse Gas Control Technologies >DEMONSTRATION OF INHERENT CO_2 SEPARATION AND NO NO_x EMISSION IN A 50kW CHEMICAL-LOOPING COMBUSTOR: CONTINUOUS REDUCTION AND OXIDATION EXPERIMENT
【24h】

DEMONSTRATION OF INHERENT CO_2 SEPARATION AND NO NO_x EMISSION IN A 50kW CHEMICAL-LOOPING COMBUSTOR: CONTINUOUS REDUCTION AND OXIDATION EXPERIMENT

机译:固有的CO_2分离和50kW化学循环燃烧器中没有NO_X排放的示范:连续减少和氧化实验

获取原文

摘要

The purpose of this study is to demonstrate inherent CO_2 separation, no NOx emission, high CO_2 selectivity, high CH_4 conversion, and no side reaction (carbon deposition and/or hydrogen generation) in a chemical-looping combustion system by continuous reduction and oxidation experiment in a 50kWth chemical-looping combustor. NiO/bentonite particle was used as a bed material and CH_4 and air were used as reacting gases for reduction and oxidation, respectively. A total operating time of more than 3.5 hour was accomplished. Pressure drop profiles in the system loop were maintained steadily throughout 3.5 hour run and solid circulation between an oxidizer and a reducer was smooth and stable. By analysis of gases in the exit stream from the system, we can conclude that inherent CO_2 separation and NOx-free combustion is possible in the chemical-looping combustion system.
机译:本研究的目的是通过连续减少和氧化实验,证明固有的CO_2分离,NOx发射,高CO_2选择性,高CH_4转化,高CH_4转化,以及无副反应(碳沉积和/或碳沉积和/或氢气)在50kwth化学循环燃烧器中。使用NiO /膨润土颗粒作为床材料,CH_4和空气分别用作反应气体进行还原和氧化。完成了超过3.5小时的总操作时间。系统环路中的压降曲线在整个3.5小时的运行过程中保持稳定,氧化剂与减速器之间的固体循环平滑且稳定。通过从系统的出口流中的气体分析,我们可以得出结论,在化学环燃烧系统中可以结论可固有的CO_2分离和无氮燃烧。