The effect of column shape on seismic performance of 3D RC framed structures with and without infill walls using pushover analysis

机译:柱状对3D RC框架结构的抗震性能,使用Pushover分析

获取原文

摘要

A ground + six storey RC space frame model with two 3m x 3m panels in each plan direction and two 3m x 4.5m panels in each principal plan direction are selected. A comparison is made between the model having the rectangular cross section of columns and the equivalent square cross section. The same models were also analyzed considering brick wall elements in the periphery of the frame. The results obtained from the nonlinear static pushover analysis performance indicate that the plastic hinges formed in the frame with square shaped columns are less severe for both of the models. It was also observed that the models with peripheral brick walls indicate a similar behaviour. It can be concluded that the square shape of the column cross section improves the seismic response of a structure as compared to the rectangular shape of an equivalent area.
机译:一个地面+六层RC空间框架模型,每个平面方向上有两个3m x 3M面板,每个主平面方向都有两个3m x 4.5m面板。在具有列的矩形横截面和等效方横截面的模型之间进行比较。考虑到框架周边的砖墙元件,还分析了相同的模型。从非线性静态推送分析性能获得的结果表明,对于两种型号,在具有方形柱中形成的塑料铰链不太严重。还观察到,外围砖墙的模型表示类似的行为。可以得出结论,与等效区域的矩形形状相比,柱横截面的方形改善了结构的地震响应。