首页> 外文会议>International Conference on Multi-Material Micro Manufacture >A novel setup for cavity pressure and temperature measurements in micro-injection moulding
【24h】

A novel setup for cavity pressure and temperature measurements in micro-injection moulding

机译:微注射成型中腔压力和温度测量的新型设置

获取原文

摘要

In injection moulding, continuous monitoring of temperature and pressure parameters in the mould cavity is very important for process control and optimization. In the micro injection moulding process, however, it is more difficult to measure the cavity pressure and temperature due to the extremely small sizes involved. In this paper, a novel setup for cavity pressure and temperature measurements is presented: a miniaturized p,T quartz sensor is used to measure both pressure and temperature directly in the middle of the mould cavity and a data acquisition system has been developed in order to collect signals provided by the sensors. It was demonstrated the suitability of the novel setup to micro injection moulding and that it can be easily applied to any micro injection moulding machine.
机译:在注塑成型中,在模腔中的温度和压力参数的连续监测对于过程控制和优化非常重要。然而,在微注塑成型过程中,由于所涉及的极小尺寸,更难以测量腔压力和温度。在本文中,提出了一种用于腔压和温度测量的新颖设置:小型化P,T石英传感器用于测量直接在模腔中间的压力和温度,并开发了数据采集系统以便收集传感器提供的信号。它展示了新颖的设置对微注塑成型的适用性,并且可以容易地应用于任何微注塑机。