首页> 外文会议>International Astronautical Congress >Experimental Study of Low Density Thermal Insulation Materials on Radiation Heating Facility with Variable Pressure
【24h】

Experimental Study of Low Density Thermal Insulation Materials on Radiation Heating Facility with Variable Pressure

机译:低密度隔热材料对可变压力辐射加热设施的实验研究

获取原文

摘要

In order to evaluate the thermal insulation performance of low density thermal insulation materials, China Academy of Aerospace Aerodynamics (CAAA) has developed the radiation heating facility with variable pressure. The facility includes 0~150kW quartz lamps heater, test chamber, vacuum system and control system. The maximum running time of the facility is 4000s. The surface temperature of low density thermal insulation materials is up to 1000K. The minimum pressure in the test chamber is 10Pa. The performances of low density thermal insulation materials in deferent low pressures have been researched on the facility. The model cross size is 100mm in long and 100mm in width. The results show that, at the same test condition, the density and pressure will affect the thermal insulation performance of materials. Decreasing the pressure or decreasing density will improve the thermal insulation performance.
机译:为了评估低密度保温材料的绝热性能,中国航空航天院(CAAA)开发了具有可变压力的辐射加热设施。该设施包括0〜150kW石英灯加热器,测试室,真空系统和控制系统。设施的最大运行时间为4000s。低密度绝热材料的表面温度高达1000K。测试室中的最小压力是10Pa。在设施上研究了延迟低压下低密度绝热材料的性能。模型交叉尺寸为100毫米,宽度为100毫米。结果表明,在相同的测试条件下,密度和压力会影响材料的绝热性能。降低压力或降低密度将提高保温性能。