首页> 外文会议>International Universities Power Engineering Conference >THE AGEING OF CAST RESIN SUBJECT TO REPETITIVE COMBINED VOLTAGES OF LOW AND HIGH FUNDAMENTAL FREQUENCIES
【24h】

THE AGEING OF CAST RESIN SUBJECT TO REPETITIVE COMBINED VOLTAGES OF LOW AND HIGH FUNDAMENTAL FREQUENCIES

机译:铸造树脂的老化经受重复组合电压的低,基本频率

获取原文

摘要

Due to the increased unbalanced loading of the electrical grids, the penetration of power electronics an the increasing number of switching phenomena in low and medium voltage grids, it is obvious that electrical insulation systems are no longer subjected to only the 50 Hz, purely sinusoidal voltages. The existence of fast transients, switching impulses or in general combined voltages with at least two clearly distinguishable frequencies affects the ageing mechanisms and expected lifetime of electrical insulation. Some typical fast transients superimposed on the main 50 Hz voltage are generated in the laboratory by using a Tesla transformer and supplied to a commonly used cast resin insulated system. One of the most important conclusions confirms that there is indeed an accelerated accumulated ageing of the resin due to the combined fast transient pulses. This ageing is also modelled by an equivalent ageing effect using only a 50 Hz sinusoidal voltage having a crest value of 127% of the highest peak value measured for the superimposed fast transients.
机译:由于电网的不平衡负荷增加,功率电子设备的渗透到低中电网中的开关现象的越来越多,显然是电绝缘系统不再受到50 Hz,纯粹正弦电压的影响。快速瞬变,切换脉冲或通常具有至少两个明显可区分频率的一般组合电压的存在影响老化机构和预期的电绝缘寿命。通过使用Tesla变压器在实验室中产生叠加在主50Hz电压上的一些典型的快速瞬变,并供应到常用的铸造树脂绝缘系统。最重要的结论之一证实,由于组合的快速瞬态脉冲,确实存在树脂的加速累积老化。该老化也是通过仅使用50Hz正弦电压的等效老化效果来建模,该曲率为叠加的快速瞬变测量的最高峰值的127%的峰值值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号