首页> 外文会议>International Conference on Flow Measurement >Research of Improving Accuracy of the 3-ton Electric Balance for Gas Flow Measurement
【24h】

Research of Improving Accuracy of the 3-ton Electric Balance for Gas Flow Measurement

机译:提高气流测量3吨电平衡准确性的研究

获取原文

摘要

There is a professional 3-ton electric balance for gas mass flow measurement in Chengdu Verification Branch for Natural Gas Flow of National Crude Oil Large Flow Rate Measurement Station. The weighting range of this balance is 0kg to 110kg, the minimum sensible mass is :1g, and the shift of indication value is no more than 2g (P=95%). It has been proved stable and reliable during its 8-year usage. This article brieves the method of improving the original circuit control system by applying advanced electrc technology. Using this method, the shift of indication value can been reduced to less than 2g and the balance can work even more stable. In addition, the author introduces an indirect weighting method to reduce the negative effect caused by the balance crossbeams and the hanging weights used after many years. Thus the accuracy of the electronic balance can be improved.
机译:成都验证分公司的天然气流量为全国原油大型流量测量站天然气流量,有专业的3吨电气平衡。这种平衡的加权范围为0kg至110kg,最小明度质量是:1g,指示值的偏移不超过2g(p = 95%)。在8年的使用过程中,它已被证明是稳定可靠的。本文通过应用先进的电气技术来推动改善原始电路控制系统的方法。使用此方法,指示值的偏移可以减少到小于2G,并且平衡可以更稳定。此外,作者介绍了一种间接加权方法,以减少由余弦横梁和多年后使用的悬挂重量引起的负效应。因此,可以提高电子平衡的准确性。