A RELAP5 model for the analysis of the PSB-VVER test facility was developed by the EREC in Russia. The PSB-VVER is a large-scale integral test facility to model the VVER-1000 type NPP. The volume and power scale in this test facility is 1:300 and the elevation scale is 1:1, which corresponds to the elevation mark of the reactor prototype. At the Division of Nuclear Safety, RIT, Sweden, we have modified the PSB-VVER facility's RELAP5 model in order to analyze two of the transient tests performed on the PSB-VVER facility, which serve as the validation matrix described by NEA/CSNI. The objective of the work conducted was to validate the results obtained from RELAP5's calculation with the supplied experimental data from the PSB-VVER test facility. Two accident scenarios have been calculated and analyzed. After being verified against the "11% UP LOCA" test data, the RELAP5/MOD3.2 model was used for a so-called "blind" transient calculation of the test "2×25% HL LOCA" and the results obtained were compared with the experimental data provided after the calculation.
机译:俄罗斯的Erec开发了一种用于分析PSB-VVER测试设施的RELAP5模型。 PSB-VVVE是一个用于模拟VVER-1000类型NPP的大规模积分测试设施。该测试设施中的音量和功率标度为1:300,高度尺度为1:1,其对应于反应器原型的高度标记。在核安全的划分,瑞典Rit,我们修改了PSB-VVER设施的RETAP5模型,以分析在PSB-VVER设施上执行的两个瞬态测试,该设施用作NEA / CSNI描述的验证矩阵。进行的工作的目的是通过从PSB-VVER测试设施提供从Relap5的计算中获得的结果。已经计算并分析了两种事故情景。在验证“11%UP LOCA”测试数据后,RETAP5 / MOD3.2模型用于所谓的“盲”瞬态计算“2×25%HL基因座”,并比较了所获得的结果通过计算后提供的实验数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号