In this study, the loss of coolant accident analysis without emergency core cooling system on in-vessel core melt progression is evaluated under a severe accident scenario in Bushehr VVER-1000 reactor. Using the RELAP5/SCDAP mod3.4 computer code, a best estimate simulation event of a 25 mm break SBLOCA, without ECCs is conducted until the reactor pressure vessel failure. In the performed analysis some important parameters such as the amount of hydrogen production, debris bed height and failure of lower plenum due to creep rupture are considered which are not included in the reactor FSAR.
机译:在这项研究中,在Bushehr VVER-1000反应堆发生严重事故的情况下,评估了在没有紧急堆芯冷却系统的情况下冷却剂事故分析对船内堆芯融化进展的损失。使用RELAP5 / SCDAP mod3.4计算机代码,进行25 mm断裂SBLOCA(无ECC)的最佳估计模拟事件,直到反应堆压力容器发生故障为止。在进行的分析中,考虑了一些重要的参数,例如产氢量,碎屑床高度和由于蠕变破裂而导致的下充气室故障,这些参数不包括在反应堆FSAR中。