首页> 外文会议>International Symposium on the Science and Technology of Light Sources >Spectroscopic Technique for Cathode Fall Diagnostics in Fluorescent Lamps
【24h】

Spectroscopic Technique for Cathode Fall Diagnostics in Fluorescent Lamps

机译:荧光灯阴极秋季诊断的光谱技术

获取原文

摘要

We report here the use of measurements of the time dependence and intensity of emission of rare-gas spectral lines in the negative glow as a cathode fall diagnostic in fluorescent lamps. For argon buffer gas, the relevant energy levels and spectral lines are shown in Fig 1. The 420 nm violet line is emitted in a transition between the 5p state at 14.50 ev and the metastable state at 11.55 ev. The 811.5 nm infra-red line is emitted in a transition between the 4p state at 13.08 ev and the metastable state at 11.55 ev.
机译:我们在此报告使用在负光发光中的稀有气体光谱线的排放时间依赖性和强度的测量作为阴极落下荧光灯。对于氩气缓冲气体,相关的能量水平和光谱线如图1所示。420nm紫线在14.50eV处的5P状态和11.55eV的亚稳态之间发射。 811.5 nm红外线在13.08eV的4P状态之间的过渡中发射,在11.55eV处的亚稳态。