【24h】

Biological solution to storm water?

机译:雨水的生物解决方案?

获取原文

摘要

Standard practice in Flanders is to limit the hydraulic capacity of sewage treatment works to 6Q_(14) (Q_(14)= 1.7 dry weather flow Q_(DWF)). A maximum of 3Q_(14) is treated biologically, while the excess flow undergoes only physical treatment in storm tanks. This practice has been challenged by a new high-flow activated sludge operation concept, consisting of the treatment of the full storm sewage flow in the biological train and of the use of the storm tanks as additional secondary clarifiers. After successful testing in two installations, 56 works of different sizes and types were switched to high-flow activated sludge operation from 1999 to 2002. This paper reports on progress and experiences gained since then. The analysis focuses on the parameters subject to regulatory discharge (BOD, COD, suspended solids, total nitrogen and total phosphorus) plus ammonia. Special attention is paid to the performance of the clarification and of the nitrification processes. The results indicate that high-flow biological treatment provides a substantial reduction in wet weather discharges while maintaining acceptable process operating conditions.
机译:在弗兰德标准做法是污水处理厂的液压容量限制到6Q_(14)(Q_(14)= 1.7干燥天气流量Q_(DWF))。最大3Q_的(14)被生物处理过的,而多余的流动在风暴罐仅经历物理处理。这种做法已被新的高流量的活性污泥操作概念的挑战,包括在生物系和使用风暴坦克作为附加第二级澄清池的治疗的全部风暴污水流量的。在两个安装测试成功后,不同规模和类型的56件作品被切换到高流量的活性污泥操作从1999年到2002年。自那时以来取得的进展和经验,这纸报告。分析集中于该参数受到监管放电(BOD,COD,悬浮固体,总氮和总磷)加氨。特别注意的是要澄清的性能和硝化过程。结果表明,高流动生物处理在潮湿的天气放电提供了一个显着减少,同时保持可接受的工艺操作条件。