Secondary settling dynamics at maximal capacity were investigated at a full scale wastewater treatment plant which utilizes a unique process solution incorporating pre-denitrification with post-nitrification in nitrifying trickling filters. Since nitrogen removal is greater when more secondary effluent is recirculated to the trickling filters, the secondary settlers generally operate at close to their maximal capacity. The settling and flocculation properties of the activated sludge are therefore a major capacity-determining factor for plant operation. Due to the short sludge age, the flocculation properties, with respect to both thickening and clarification, can change quickly. The dynamics in these changes were studied and the factors that determine the maximal settling capacity were assessed. Solids flux curves were constructed from batch settling tests and compared with the actual maximal settling capacities.
机译:在全尺度废水处理厂上研究了最大容量的二次沉降动力学,该储存厂采用独特的工艺溶液,其掺入硝化后硝化的硝化滴滤网。当氮气去除更大的时候,当再循环到滴流过滤器时,辅助沉降剂通常在接近其最大容量时操作。因此,活性污泥的沉降和絮凝性能是植物操作的主要能力确定因素。由于短污泥年龄短,相对于增稠和澄清的絮凝性能可以快速变化。研究了这些变化中的动态,并评估了确定最大沉降能力的因素。固体通量曲线由批量沉降试验构成并与实际的最大沉降能力进行比较。