Glass surface temperature can be measured using a radiation thermometer operating at a mid-IR wavelength, typically the 3-5 (mu)m band, where the glass is opaque. For optical fiber preforms, the temperature measurement requirement may exceed 2,200 deg C. Scale realization at national measurement institutes at these temperatures is usually carried out at short wavelengths, typically less than 1 (mu)m. The mismatch in wavelength can lead to significant uncertainties when calibrating a radiation thermometer working at 3-5 (mu)m. To overcome this, a narrow band 3.95 (mu)m radiation thermometer has been built that is designed to be used from 1,000 to 2,500 deg C. It is calibrated by measurement of high-temperature metal-carbon eutectic fixed-points. The instrument is based on silicon lenses, with a liquid nitrogen (LN_(2))-cooled InSb detector, and narrow-band interference filter. An anti-reflection coated objective lens/aperture stop focuses onto a field stop giving a 1 mm target, then a collimating lens, and glare stop. All parts visible to the detector, other than the target area, are either at LN_(2) temperature or are part of a temperature-stabilized housing. A relay-operated shutter that blocks the field stop is used to subtract the background. The size-of-source effect of the instrument has been measured. Gold-point measurements have been made to assess the stability. The device has been calibrated using high-temperature fixed points. A three-parameter fit has been applied and the resultant scale compared to an ITS-90 realization.
机译:可以使用在Mid-IR波长下操作的辐射温度计测量玻璃表面温度,通常是3-5(mu)m频带,其中玻璃是不透明的。对于光纤预制件,温度测量要求可能超过2,200℃。在这些温度下的国家测量机构的规模实现通常在短波长下进行,通常小于1(mu)m。波长的不匹配可能导致在校准在3-5(mu)m工作时的辐射温度计的显着的不确定性。为了克服这一点,已经建造了一个窄带3.95(mu)辐射温度计,其设计用于1,000至2,500℃。通过测量高温金属 - 碳共晶定位点来校准它。仪器基于硅透镜,具有液氮(LN_(2))冷却的INSB检测器和窄带干涉滤波器。抗反射涂覆的物镜/孔径停止聚焦在一个现场挡块上,该磁场停止给出1毫米的目标,然后是准直透镜,并眩光停止。除目标区域以外的探测器可见的所有部件在LN_(2)温度下或是温度稳定壳体的一部分。继电器操作的快门,该挡板块用于减去背景。已经测量了仪器的源极效应。已经进行了金点测量来评估稳定性。该装置已经使用高温固定点校准。与ITS-90实现相比,已应用三参数拟合并得到的比例。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号