首页> 外文会议>International Power Electronics Conference >A Simple Active Method to Avoid the Balancing Losses of DC Link Capacitors
【24h】

A Simple Active Method to Avoid the Balancing Losses of DC Link Capacitors

机译:一种简单的主动方法,可以避免直流链路电容的平衡损耗

获取原文

摘要

DC voltage links of three-phase power converters very often are equipped with a series connection of two electrolytic capacitors due to the high voltage level. In general, resistors arranged in parallel to each capacitor are necessary for balancing the capacitor partial voltages. The balancing resistors have to be dimensioned regarding the worst-case condition of the capacitor leakage currents, resulting in high permanent dissipative losses. To avoid these losses to a large extent, a novel simple and low-cost active circuit to replace the passive balancing resistors by a cascode array of low-cost small-signal low-voltage bipolar transistors is presented. The paper describes the operating principle of the circuit, analyzes the fundamental relationships being relevant for the balancing characteristic and gives guidelines concerning component selection. Furthermore, simulation results as well as measurements taken from a laboratory prototype are presented.
机译:三相电源转换器的直流电压链路通常经常配有由于高电压电平的两个电解电容器的串联连接。通常,对每个电容器的平行布置的电阻是平衡电容器部分电压的必要条件。平衡电阻必须对电容器泄漏电流的最坏情况条件的尺寸设计,导致高永久耗散损耗。为了避免在很大程度上避免这些损失,提出了一种通过CASCODE阵列更换无源平衡电阻的简单和低成本的有源电路。本文描述了电路的工作原理,分析了与平衡特性相关的基本关系,并给出了有关组件选择的指导。此外,提出了仿真结果以及从实验室原型取出的测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号