首页> 外文会议>International universities power engineering conference >ATTENUATION OF HARMONICS GENERATED BY THE STATIC INVERTERS
【24h】

ATTENUATION OF HARMONICS GENERATED BY THE STATIC INVERTERS

机译:静态逆变器产生的谐波的衰减

获取原文

摘要

The static inverters absorb no sinusoidal currents and generally consume a reactive power. These two phenomena produce some disturbances like the dysfunction of equipment in the worst cases. In this article, the disturbances produced by the static inverters were studied and some solutions aiming their attenuation were presented. All the same, we consider their elimination by using suitable control devices. We proceeded at the beginning with the identification of the harmonics produced by rectifiers and frequency converters, and then we study the methods of attenuation by control. The techniques used here consist in first on the association of the rectifiers in Seri, and finally the techniques of Pulse Width Modulation (PWM) and Pulse Positions Modulation (PPM) applied to Graetz bridge rectifiers.
机译:静态逆变器吸收无正弦电流并通常消耗无功功率。这两种现象在最糟糕的情况下产生了一些像设备功能障碍的障碍。在本文中,研究了静态逆变器产生的扰动,并提出了一些旨在其衰减的解决方案。一切都一样,我们考虑使用合适的控制装置消除它们。我们在开始时进行了识别整流器和变频器产生的谐波,然后我们通过控制研究衰减方法。这里使用的技术首先在SERI中的整流器结合,最后应用于应用于Graetz桥梁整流器的脉冲宽度调制(PWM)和脉冲位置调制(PPM)的技术。