High-frequency loss in transformer windings using stranded wire is analyzed. A complete loss prediction method is presented. The interstrand resistivity, which is an important parameter to determine the power loss, is measured experimentally. The analytical model is solved to get an optimal pitch, which specifies the degree of twisting that results in minimum loss. A transformer using a stranded wire winding is built and measured. The model prediction is verified to have high accuracy in the frequency range up to 100 kHz. Compared with the same transformer using a solid wire winding, about 67 percent less power loss at 100 kHz is achieved using stranded wire. Using the loss-prediction model provided in this paper, engineers will be able to control eddy-current losses in high-frequency transformer and inductor windings using stranded wire at a relatively low cost compared to using litz wire.
机译:分析了使用绞合线的变压器绕组中的高频损耗。提出了一种完整的损失预测方法。实验测量是确定功率损耗的重要参数的Interstrand电阻率。解析模型得到解决以获得最佳音高,这指定导致最小损耗的扭曲程度。建造并测量使用绞线绕组的变压器。验证模型预测在频率范围内具有高达100 kHz的高精度。与使用固体线绕组的相同变压器相比,使用绞合线实现了100kHz的约67%的功率损耗。使用本文提供的损耗预测模型,与使用LITZ线相比,工程师将能够使用绞线以相对较低的成本控制高频变压器和电感绕组中的涡流损耗。