首页> 外文会议>International Conference on Environmental Systems >Performance testing of a new membrane evaporator for the thermoelectric integrated membrane evaporator system (TIMES) water processor
【24h】

Performance testing of a new membrane evaporator for the thermoelectric integrated membrane evaporator system (TIMES) water processor

机译:用于热电集成膜蒸发器系统(次)水处理器的新膜蒸发器的性能测试

获取原文

摘要

The TIMES system was evaluated to determine its ability to process reverse osmosis (RO) brine as one of the Advanced Water Processor steps. Since preliminary testing performed in 1998 showed that the membrane typically used in the process (Nafion 117) offered a very poor ammonia rejection, a search for an alternate membrane exhibiting high ammonia rejection capability was initiated under NASA-JSC funding. This investigation has resulted in the selection of a PolyVinylAlcohol (PVA) composite membrane as a replacement. When processing RO brine and untreated human urine as feeds, the Pervap 2201 membrane showed a 96% ammonia rejection over a large range of ammonia concentration. The water permeation rates in both laboratory-scale and pilot scale testings were also similar to the Nafion. The water permeance of the Pervap 2201 was approximately 7.5 kg/h/m{sup}2/atm (1.1 lb/h/m{sup}2/psi).
机译:评估时代系统以确定其处理反渗透(RO)盐水作为先进水处理器步骤之一的能力。由于1998年进行的初步测试表明,在该过程中通常使用的膜(Nafion 117)提供了非常差的氨排斥,因此在NASA-JSC资金下启动了对表现出高氨排斥能力的替代膜的搜索。该研究导致选择聚氯乙醇(PVA)复合膜作为替代品。当加工RO盐水和未经处理的人尿剂作为饲料时,静脉2201膜在大范围的氨浓度上显示出96%的氨排斥。实验室规模和试验规模测试中的水渗透率也与Nafion相似。 Pervap 2201的水渗透率约为7.5kg / h / m {sup} 2 / atm(1.1 lb / h / m {sup} 2 / psi)。