This paper details a study on the detectability of dry contact kissing bonds in adhesive joints using three ultrasonic inspection techniques. Conventional normal incidence longitudinal and shear wave inspection were conducted on dry contact kissing bonds using a standard immersion transducer and an EMAT respectively. The detectability of the dry contact kissing bonds was assessed by calculating the reflection coefficient of the interface at varying loads for a number of surface roughnesses. A high power ultrasonic method was also employed to determine the non-linear behavior of the adhesive interface. The non-linearity of the interface was determined by the ratio of the amplitudes of the first harmonic and fundamental frequencies of the transmitted waveform. It was found that the high power technique showed the greatest sensitivity to kissing bonds at low contact pressures, however at high loads conventional longitudinal wave testing was more sensitive. It was also noted that a combination of two or more techniques could provide enhanced information about the kissing bond compared to a single technique alone.
机译:本文详述了使用三种超声检查技术的粘合接头中干接触接吻键的可检测性的研究。使用标准浸没式换能器和EMAT在干燥接触接吻键上进行常规的正常发射纵向和剪切检测。通过计算在多个表面粗糙度下的不同负载下的界面的反射系数来评估干触点接吻键的可检测性。还采用了高功率超声波方法来确定粘合剂界面的非线性行为。界面的非线性由第一谐波和发射波形的基本频率的幅度的比率确定。发现高功率技术对在低接触压力下对接触粘合的最大敏感性最大,但是在高负载下,传统的纵向波测试更敏感。还应注意,与单独的单一技术相比,两种或更多种技术的组合可以提供关于接吻键的增强信息。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号