The new acoustic means of breathing airgas flow rate measurement is described. The main feature - special air-metric channel, supplied with ceramics electro-acoustic transducers. The principle of its operation is based on the dependence of the velocity of the acoustic vibrations arriving at the receiver upon the air-gas velocity. The device does not disturb the aerodynamic structure of the flow, has no moving elements and is very sensitive and precise.
机译:描述了新的呼吸气凝捕速率测量的声学装置。主功能 - 特殊空调通道,配有陶瓷电声传感器。其操作原理基于在气体气体速度上到达接收器的声振动的速度的依赖性。该装置不会干扰流动的空气动力学结构,没有移动元件并且非常敏感和精确。