【24h】

Air pollution modeling surrounding Serdang Power Station

机译:Serdang Power Station周边的空气污染造型

获取原文

摘要

In this study, the level of NO_x and SO_2 concentrations in the surrounding areas of Serdang Power Station have been calculated using ISCST3 dispersion model. The 256 grids defined in area of 22km x 22km are accepted as receptor grids and the contribution of emission from the existing Serdang Power Station has been used as an input data. The maximum 1-hr averaging ground level concentration of NO_x and SO_2 predicted by the model are 134.17 μg/m~3 and 159.31 μg/m~3 at distance of 1.5 km southeast of the plant. However, these levels are well within the Malaysian Ambient Air Quality Standards 1990 and the World Health Organisation (WHO) Guidelines 1999. The model was validated by comparing the model output and actual field measurement with 95% of the accumulative frequency distribution by a factor of less than 2. Results of the study revealed that the ah- pollution dispersion from the Serdang Power Station are within the acceptable exposure limit to human health as stated in Malaysian Ambient Air Quality Standards 1990 and the World Health Organisation
机译:在该研究中,使用ISCST3分散模型计算了Serdang电站周围区域的NO_X和SO_2集中的水平。在22km x 22km面积中定义的256个网格被接受为受体电网,并且来自现有的Serdang电站的发射的贡献已被用作输入数据。由模型预测的NO_X和SO_2的最大1-HR平均接地浓度为134.17μg/ m〜3和159.31μg/ m〜3,距离植物东南部1.5千米。然而,这些水平在马来西亚环境空气质量标准1990和世界卫生组织(WHO)指南1999中。通过将模型输出和实际现场测量与95%的累积频率分布进行比较,通过将模型输出和实际频率分布进行比较来验证该模型小于2.该研究结果表明,Serdang Power Station的AH-污染分散在马来西亚环境空气质量标准1990年和世界卫生组织中所述的人类健康的可接受暴露限制

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号