NEW GENERATION OF LIQUID FLOW SENSORS FOR THE NANOLITER THROUGH MILLILITER PER MINUTE RANGE WITH EXTREMELY SMALL INTERNAL VOLUME

机译:新一代纳米液体的液体流动传感器通过毫升/分钟范围内的内部体积极小

获取原文

摘要

In this paper, a new generation of liquid flow sensors has been presented that is capable of meeting the requirements as imposed by the life science, analysis, biotech and other markets. The actual flow sensor consists of a straight flow tube with two active elements around it. The internal diameter of the flow tube may vary between 20 and 200 μm. The corresponding internal volume is 15 nanoliter and 1.5 microliter, respectively, which is extremely small. Several instruments have been built in which the wetted material of the flow tube was either stainless steel, fused silica or PEEK. The feasibility of other materials suitable for the above mentioned markets will be further investigated. The flow sensors have been driven with two different measurement principles, namely the constant power (CP) and the constant temperature (CT) method. The CP measurement principle proved to be useful for flow ranges below circa 100 microliter/min, the CT measurement principle was suited for flow ranges above circa 100 microliter/min. The tested instruments were capable of measuring flow ranges between 25 .. 500 nanoliter/min. (smallest flow range) and 100 .. 2000 microliter/min. (largest flow range) water. These flow ranges will be further extended, both downwards and upwards. Moreover, measurements on other liquids will be performed. The measured response time of the flow sensors is of the order of t_(98%) ≈ 2 seconds. The feasibility of the new measurement concept for low liquid flows has been proven. In due time, products based upon this new technology will be commercially available.
机译:本文介绍了新一代液体流动传感器,其能够满足生命科学,分析,生物技术和其他市场所施加的要求。实际流量传感器由具有两个周围有两个有源元件的直流管组成。流动管的内径可以在20至200μm之间变化。相应的内部体积分别为15纳米,分别为1.5微升,这是非常小的。已经建成了几种仪器,其中流管的湿润材料是不锈钢,熔融二氧化硅或偷看。将进一步研究适用于上述市场的其他材料的可行性。流动传感器已经用两种不同的测量原理驱动,即恒功率(CP)和恒温(CT)方法。 CP测量原理被证明是在大约100微升/分钟以下的流量范围的流量,CT测量原理适用于大约100微升/分钟的流量范围。经过测试的仪器能够测量25. 500纳米罐/分钟之间的流量范围。 (最小流量范围)和100。2000微升/分钟。 (最大流量范围)水。这些流量范围将进一步扩展,双向和向上。此外,将进行对其他液体的测量。流动传感器的测量响应时间为T_(98%)≈2秒。已经证明了低液体流量的新测量概念的可行性。在适当的时候,基于这项新技术的产品将可商购。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号