首页> 外文会议>Mexican Symposium on Medical Physics >Dose distributions in prostate brachytherapy: comparison between Sievert and Monte Carlo methods
【24h】

Dose distributions in prostate brachytherapy: comparison between Sievert and Monte Carlo methods

机译:前列腺近距表中的剂量分布:Sievert和Monte Carlo方法之间的比较

获取原文

摘要

In the present work we discuss two numerical methods for the calculation of 3D spatial dose distributions, and their application in HDR prostate brachytherapy. We include a comparison between the results obtained with the Sievert integral method and the use of tables generated by Monte Carlo simulations of radiation transport in a homogeneous medium for two types of 192{sup left}Ir encapsulated sources commonly used in Mexican hospitals. The application of both methods to clinical data is also presented.
机译:在本工作中,我们讨论了两种用于计算3D空间剂量分布的数值方法,以及它们在HDR前列腺近距离放射治疗中的应用。我们包括用Siever Integry方法获得的结果与Monte Carlo模拟在均匀介质中使用的辐射传输中的辐射传输中的辐射传输产生的表格之间的比较,用于两种类型的192 {sup} IR封装来源,尤其是墨西哥医院。还提出了两种方法对临床数据的应用。