首页> 外文会议>Conference on recent developments in traceable dimensional measurement >Automatic high precision calibration system for angle encoder (II)
【24h】

Automatic high precision calibration system for angle encoder (II)

机译:角度编码器自动高精度校准系统(II)

获取原文

摘要

This paper describes the automatic calibration system for an angle encoder which is installed at the AIST (National Institute of Advanced Industrial Science and Technology). The system uses the Equal-Division-Averaged (EDA) method that is one kind of the self-checking method. This system has grate performance of the calibration with small uncertainty. In this paper we try to explain the factor of uncertainty of this system. The dominant uncertainty factor is the eccentricity of shaft between the system and an external rotary encoder. The influence from other factors is very small about 0.01" or less.
机译:本文介绍了安装在AICT(国家高级工业科学技术研究所)安装的角度编码器的自动校准系统。该系统使用是一种自检方法的等平均(EDA)方法。该系统具有小不确定性的校准的灰色性能。在本文中,我们试图解释该系统的不确定性因素。主导的不确定性因素是系统与外部旋转编码器之间的轴的偏心率。其他因素的影响非常小约0.01“或更小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号