The use of special moment resisting frames (SMRF) in tall story buildings presents a problem of drift control. Plate girders of depths of 40 inches or greater are normally required for SMRF which present problems of ductility in SMRF connections. This paper presents a new concept in tall story buildings such as a convention center, referred to as a Coupled Girder Moment Resisting Frame (CGMRF) which uses two girders at each floor and couples them using vertical links. Use of Friction Dampers and CGMRF to reach the project performance goals is discussed. Connection testing and non-linear push over analysis results are presented that show ductility in the system in a two-phase yielding of the vertical links followed by the girders. Connection design procedures are also presented.
机译:在高层建筑中使用特殊力矩抵抗框架(SMRF)呈现了漂移控制的问题。 SMRF通常需要40英寸或更大的深度或更大的板梁,其在SMRF连接中存在延展性问题。本文介绍了一个新的概念,例如会议中心,如会议中心,称为耦合梁矩抵抗框架(CGMRF),它在每个楼层使用两个梁,并使用垂直链接耦合它们。讨论了使用摩擦阻尼器和CGMRF将达到项目性能目标。介绍了连接测试和非线性推动过度分析结果,其在系统中显示延展性在系统中的垂直链路之后的两相屈服。还提出了连接设计程序。