Field and Laboratory Detection of AC Corrosion Using High-Sensitive ER-Technology

机译:使用高敏感的ER-Technology对AC腐蚀的场和实验室检测

获取原文

摘要

This paper states that high sensitivity ER sensors can be applied with great success and as a necessary tool in AC corrosion detection. The effect of the coating defect size (and geometry) is observed in both ohmic spread resistance and polarisation behaviour (diffusion and charge transfer kinetics. Spread resistance is entirely in control of the density of the AC current. In turn, for certain AC polarisation behaviour, AC current density conducts the peak values in off-potential and corrosion behaviour. The coating defect size accordingly becomes a very important parameter when designing coupons in general and ER sensors in particular.
机译:本文指出,高灵敏度ER传感器可呈现出巨大的成功,并作为交流腐蚀检测的必要工具。在欧姆抗施力和偏振行为中观察到涂层缺陷尺寸(和几何)的效果(扩散和电荷转移动力学。抗膨胀性完全控制交流电流的密度。反过来,对于某些AC极化行为,AC电流密度在剥离电位和腐蚀行为中传导峰值。涂层缺陷尺寸相应地成为设计一般和ER传感器的优惠券时是一个非常重要的参数。