Within the frame of the development of a method for the measurement of concentration levels from 0.003 to 10 parts per billion by volume of hexachlorobutadiene in indoor air an assessment has been performed of the uncertainty of the measurement results. This assessment - fully based on the principles of the ISO Guide to the Expression of Uncertainty in Measurement (ISO-GUM) - has shown that - even for the measurement of such extremely low concentrations - uncertainty levels of < 25% (95% confidence) are achievable.
机译:在开发框架内,用于测量浓度水平从0.003至10亿百左右的室内空气中六氯丁二烯体积的六氯丁二烯,对测量结果的不确定性进行了评估。本评估 - 完全基于ISO指南的原理表达测量不确定性(ISO-GUM) - 表明 - 甚至用于测量这种极低浓度 - 不确定水平<25%(95%的置信度)可实现。