With the aim to characterise material changes due to irradiation exposure, the possibility of using magnetic measurements have been continuously studied. In this work, a further study is described dealing with a reactor pressure vessel (RPV) shell of a Russian WWER-1000 nuclear power plant type. The shell has been cut into blocks and finally several sets of Charpy specimens were manufactured and a large fraction of them exposed to neutron irradiation in the High Flux Reactor (HFR), Petten, of the JRC-IE, in order to assess irradiation effects on the given 15Kh2MNFAA low alloy steel. The irradiation was carried out at 290°C and a t a fluence of 1.8 1023 n.m-2 (E>1 MeV). The scope of this paper is to present the evaluation of the effect of irradiation on magnetic properties and its possible relation to mechanical properties changes, as a consequence of embrittlement on irradiated Charpy specimens. In this case the Charpy specimens were standard full size CV-n type with very well known cutting orientation with reference to the original pressure vessel shell. This is very important since the cutting orientation of specimen often have such strong effect on the magnetic Barkhausen signal to mask the irradiation effects on specimens The magnetic measurements carried out included Barkhausen signal and the so called RXI value; which is the relative induction values to changing on intensity of magnetic flux within the specimen. The results highlight the necessity to treat magnetic measurements on Charpy specimens in a statistical way.
机译:旨在表征由于照射暴露引起的材料变化,连续研究了使用磁测量的可能性。在这项工作中,描述了俄罗斯WWER-1000核电厂类型的反应器压力容器(RPV)壳的进一步研究。将壳切成块,最后制造了几套夏比样品,并且将大部分暴露于JRC-IE的高通量反应器(HFR),Petten中的中子辐射,以评估辐照效应给定的15kh2mnfaa低合金钢。在290℃下进行辐射,并为1.81023 n.m-2(e> 1 mev)的流量。本文的范围是在辐照夏虫标本的脆化因脆化时呈现对磁性辐射对磁性的影响及其与机械性能变化的影响。在这种情况下,夏比标本是标准全尺寸CV-N型,其具有非常众所周知的切削方向,参考原始压力容器壳。这是非常重要的,因为样本的切割方向通常对磁性Barkhausen信号具有如此强烈的影响,以掩盖对样品的辐射效应,所以磁测量包括Barkhausen信号和所谓的RXI值;这是改变样品内磁通量强度的相对感应值。结果突出了以统计方式对夏皮标本对磁性测量进行治疗的必要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号