When leak-testing parts with the tracer gas method, the "no-indication" response of the leak detector leaves the operator with the question whether there is really no leak present or the test instrument may be in a faulty (= insensitive) condition. Moreover, an operator being absent-minded or distracted may easily move the sniffer tip to the wrong spot on the test object or at least not to all required test areas. To make sure that the uncertainty about sensitivity is avoided specific artificial leaks ("test leaks") are routinely used for frequent verification of the correct function and calibration of the leak detector. However, absent-minded, distracted or even lazy operators are not detected in this way. Recent software features implemented into INFICON leak detectors can help prevent mistakes of the above kind. Such features include intelligent filtering of the signal (preventing spurious noise), suppression of interfering gas effects, dynamic zeroing of the signal, simple on-site function tests with a built-in test leak, a complete spectrum of indications (optical, acoustical, tactile...) if the trigger for leaky objects is exceeded and more. As an example of the latest achievements in this field the operator-controlling features of the new ECOTEC E3000 refrigerant leak detector from INFICON are described in some detail. It will become quite clear that product quality (in this case of refrigerators and air conditioners) is greatly enhanced by such supervising functions.