首页> 外文会议>European conference on industrial furnaces and boilers >Measurement of gas-velocity in a large coal burner test rig
【24h】

Measurement of gas-velocity in a large coal burner test rig

机译:大型煤炭燃烧器试验台气速度测量

获取原文

摘要

In the present work, results of gas velocity measurements with a newly developed vane anemometer (HTA ― High-Temperature-Anemometer) are compared with results of measurements obtained from Laser Doppler Anemometer (LDA). The measurements were carried out at the combustion test rig of ALSTOM Combustion Services Ltd. in Derby/UK, and demonstrate the usability and accuracy of the High-Temperature-Anemometer under severe conditions. The test rig was provided with a triple register low NOx coal burner firing pulverised Colombian blended coal at a constant thermal load of 30 MW. Although the environment was both very hot (up to 1350°C) and dust laden, the vane anemometer worked with an accuracy comparable to the reference LDA measurement. Since the anemometer represents a relatively simple to use and low cost option compared with LDA, it is seen as a viable alternative for gas velocity measurements in difficult environments. The measurement results are also demonstrated to compare favourably with the results from CFD calculations of the flow in the combustion chamber of the test rig.
机译:在本作工作中,将气体速度测量结果与新开发的叶片风速计(HTA - 高温气体计)进行比较,与激光多普勒风速计(LDA)获得的测量结果进行比较。测量在德比/英国阿尔斯通燃烧服务有限公司的燃烧试验钻机上进行,并在严重条件下证明了高温风速计的可用性和准确性。在恒定的热载荷为30mW的恒定热负荷下,试验台提供三重寄存器低NOx煤炭燃烧器烧制粉碎的哥伦比亚混纺煤。虽然环境既非常热烈(最多1350°C)和载荷,则叶片风速计的精度都适用于参考LDA测量。由于风速计代表了与LDA相比的相对简单的使用和低成本选择,因此它被视为困难环境中的气体速度测量的可行替代方案。还证明了测量结果以优于比较试验台的燃烧室中的流动的CFD计算结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号