首页> 外文会议>日本伝熱シンポジウム >MRI measurement of three velocity components of interstitial flow in packed bed
【24h】

MRI measurement of three velocity components of interstitial flow in packed bed

机译:填充床间隙流动速度分量的MRI测量

获取原文
获取外文期刊封面目录资料

摘要

Three velocity components of interstitial flow and pore structure in packed bad have been measured using magnetic resonance imaging to understand mass transport phenomena in porous media. The obtained velocity maps showed that channel flows with higher velocity existed in large void space, and that swirl flow was induced in the space where higher velocity flows combined. These nonuniform flows influence strongly dispersion process of mass transport. Based on measured velocity field in packed bed, Peclet number was calculated with approximately 20~30.
机译:使用磁共振成像来测量包装坏的间隙流动和孔隙结构的三个速度分量,以了解多孔介质中的大规模运输现象。所获得的速度图显示,具有较高速度的通道流量在大的空隙空间中存在较高,并且在更高速度流动的空间中诱导旋流。这些非均匀流量影响大规模转运的强分散过程。基于填充床中的测量速度场,用大约20〜30计算Peclet数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有