摘要

In the transmission CT imaging system with scintillator-CCD detector using synchrotron monochromatic x-ray as sheet beam, improvement of reconstructed image quality is investigated. The properties of experimental facilities cause the incident beam intensity to be spatially inhomogeneous, and to temporally attenuate. In order to achieve more reliable reconstruction, we propose the data-correction and estimation method based on the properties of the facilities and the principle of CT reconstruction, and confirm its effectiveness using a physical phantom.
机译:在具有闪烁体-CCD检测器的变速器CT成像系统中,使用同步单色X射线作为片束,研究了重建图像质量的提高。实验设施的性质导致入射光束强度在空间上不均匀,并在时间上衰减。为了实现更可靠的重建,我们提出了基于设施的特性和CT重建原理的数据校正和估计方法,并使用物理幻影确认其有效性。