首页> 外文会议>National convertion of mechanical engineers >Effect of Wind Velocity on Wind Loss Coefficient and Top Loss Coefficient of Single Glazed Flat Plate Collector―An Experimental Study
【24h】

Effect of Wind Velocity on Wind Loss Coefficient and Top Loss Coefficient of Single Glazed Flat Plate Collector―An Experimental Study

机译:风速对单玻璃平板收集器的风力损失系数和顶部损失系数的影响 - 一种实验研究

获取原文

摘要

Effect of wind velocity on wind induced convective heat transfer coefficients and top loss coefficients is investigated on a 1.21 m x 0.71 m x 0.16 m size single glazed experimental research collector. The collector is equipped with 1 kW reflective heaters kept below the absorber. The temperatures at various points are measured with 48 chromel-alumel thermocouples. The natural wind is created in a laboratory by three pedestrials fans and wind velocity is varied from 1.0 to 5 m/s along the principal axis and parallel to the collector. The input to the collector is varied from 200 W to 700 W. The wind loss and top loss coefficients are evaluated under steady state condition from energy balance equation. The variations of these coefficients are presented as a function of wind velocity on different (T_p― T_a) isotherms.
机译:在1.21M×0.71M×0.16米单玻璃实验研究收集器的1.21m×0.71M×0.16米玻璃实验研究收集器上研究了风速对风感应对流传热系数和顶部损失系数的影响。收集器配备有1 kW的反射加热器,保持在吸收器下方。用48铬铝热电偶测量各个点的温度。在实验室中产生自然风,三个训练器风扇,风速沿主轴沿1.0到5米/秒变化并平行于收集器。收集器的输入从200W到700W变化。在能量平衡方程中在稳态条件下评估风损和顶部损耗系数。这些系数的变型作为风速上的函数呈现在不同(T_P-T_A)等温线上。