首页> 外文会议>International symposium on reactor dosimetry >Reduction of Inter-Event Dead Time in Data Acquisition System for Simultaneous Measurement of Neutron Pulse Series in Time and Space
【24h】

Reduction of Inter-Event Dead Time in Data Acquisition System for Simultaneous Measurement of Neutron Pulse Series in Time and Space

机译:减少数据采集系统中的帧间事件死区时间,同时测量时间和空间中子脉冲序列

获取原文

摘要

A new data acquisition system using a position sensitive ~3He proportional counter was developed to perform simultaneous measurement of a neutron pulse train in time and space. Through an examination performed at the Kyoto University Critical Assembly, it was confirmed that the inter-event dead time of the acquisition system was 4 or 5 μs in the experimental condition. This fact shows that the inter-event dead time was reduced down to approximately a half of that of the previously developed acquisition system.
机译:开发了一种使用位置敏感〜3HE比例计数器的新数据采集系统,以在时间和空间中同时测量中子脉冲训练。通过在京都大学临界大会上进行的考试,确认采集系统的帧间死亡时间为4或5μs,在实验条件下为4或5μs。这一事实表明,事后的帧间死区时间减少到预先开发的采集系统的大约一半。