首页> 外文会议>Mine Planning and Equipment Selection Conference >OTC 21387--Aging Impact on Thermal Performance of the Aspen Wet Insulated Flowlines
【24h】

OTC 21387--Aging Impact on Thermal Performance of the Aspen Wet Insulated Flowlines

机译:OTC 21387 - 老化对白杨湿绝缘流动线的热性能的影响

获取原文

摘要

Wet insulation systems have been used in deepwater development projects in the petroleum industry for many years, with various successes and failures being observed. This paper presents a case study: the Aspen wet-insulated flowline system – the original design and the thermal performance in early days, and now after 8 years in production. Using production flow rates from the daily reports, with temperature and pressure data provided by the subsea and topsides online monitoring sensors, OLGA simulations were performed to calculate the arrival temperatures at the host and compare them against the field gathered data. Additional simulations were subsequently performed to benchmark the model thermally and determine the effective overall heat transfer coefficient of the Aspen flowline systems. This information will help the industry to better understand the performance of an aged wet insulation system.
机译:多年来,湿绝缘系统已在石油工业的深水开发项目中使用,具有各种成功和失败。 本文提出了一个案例研究:白杨湿绝缘流线系统 - 原始设计和早期的热性能,现在在生产8年后。 使用从日常报告中的生产流速,利用海底提供的温度和压力数据和在线监测传感器提供,进行OLGA模拟以计算主机的到达温度并将它们与现场收集的数据进行比较。 随后进行了额外的模拟以热量地基准,并确定Aspen流线系统的有效总传热系数。 这些信息将有助于该行业更好地了解老化湿绝缘系统的性能。