An important motivation in the development of the next generation x-ray light sources is to achieve picosecond and sub-ps pulses of hard x-rays for dynamic studies of a variety of physical, chemical and biological processes. Present hard x-ray sources are either pulse-width or intensity limited, which allows ps-scale temporal resolution only for signal averaging of highly repetitive processes. A much faster and brighter hard x-ray source is being developed at LLNL, based on Thomson scattering of fs-laser pulses by a relativistic electron beam, which will enable x-ray characterization of the transient structure of a sample in a single shot. Experimental and diagnostic techniques relevant to the development of next generation sources including the Linac Coherent Light Source can be tested with the Thomson scattering hard x-ray source. This source will combine an RF photoinjector with a 100 MeV S-band linac. The photoinjector and linac also provide an ideal test-bed for examining space-charge induced emittance growth effects. A program of beam dynamics and diagnostic experiments are planned in parallel with Thomson source development. Our experimental progress and future plans will be discussed.
机译:在下一代X射线光源的发展中的一个重要动机是实现硬X射线的PICOSECOND和子PS脉冲,用于各种物理,化学和生物过程的动态研究。存在的硬X射线源是脉冲宽度或强度受限,其允许仅用于高度重复过程的信号平均值的PS级时间分辨率。基于由相对论的电子束的FS激光脉冲的汤姆森散射,在LLN1上开发了更快,更亮的硬X射线源,这将使X射线表征样品的X射线表征在单个镜头中。与包括LINAC相干光源的下一代来源的开发相关的实验和诊断技术可以用汤姆森散射硬X射线源进行测试。此源将与100 MeV S-BAND LINAC组合RF PhotoInjector。 PhotoInjector和Linac还提供理想的测试床,用于检查空间电荷诱导的发射效果。梁动力学和诊断实验计划与汤逊源开发并行计划。我们将讨论我们的实验进展和未来计划。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号