For the problem of the measurement of leakage current of metal zinc-oxide lightning arresters (MOA) , the wavelet transform is applied to remove the noise existing in the signals. After this, the correlation analysis is applied to compute the resistive fundamental harmonic leakage current. The simulation results show that, comparing with the traditional signal processing methods, the wavelet transform can pick up the leakage current from noise satisfactorily, furthermore, it can reproduce the defection character in leakage current signal in truth, which has important meaning for early false diagnosis of equipments. By applying the correlation analysis, the measurement accuracy is highly improved, which ensure the reliability of the false diagnosis for equipments.
机译:对于金属锌氧化物雷电避雷器(MOA)漏电流的测量问题,应用小波变换以去除信号中存在的噪声。此后,应用相关性分析来计算电阻基底谐波漏电流。仿真结果表明,与传统信号处理方法相比,小波变换可以令人满意地从噪声拾取漏电电流,此外,它可以在真理中再现漏电流信号中的缺陷特征,这对早期虚假诊断具有重要意义设备。通过应用相关性分析,高度改善了测量精度,从而确保了设备的假诊断的可靠性。