摘要

Partial discharge monitoring is an effective on-line predictive maintenance test formotors and generators at 4160 volt and above, MV switchgear, as well s other electrical distribution equipment. The benefits of on-line testing allow for equipment analysis and diagnositcs during normal production. Corrective actions can be planned and implemented, resulting in reduced unscheduled downtime. An understanding of the theory related to partial discharge,a nd the relationship to early detection of insulation deterioration is required to properly evaluate this predictive maintenance tool. This paper will present a theory to promote the understanding of partial discharge technology, as well as various implementation and measurement techniques that have evolved in the industry. Data interpretation, corrective actions and application to electrical distribution equipment will also be reviewed.
机译:局部放电监测是一个有效的在线预测性维护测试符号和发电机,在4160伏特,上面,MV开关设备,也是其他配电设备。在线测试的优势允许在正常生产过程中进行设备分析和诊断。可以计划和实施纠正措施,从而减少了未核化的停机时间。理解与局部放电相关的理论,需要与早期检测绝缘劣化的关系来适当评估该预测性维护工具。本文将提出一种促进对局部放电技术的理解的理论,以及在行业中发展的各种实施和测量技术。还将审查数据解释,纠正措施和应用于电气分配设备。