首页> 外文会议>Vibration Institute annual meeting >Vibration Analysis and Compromising Balance of 4.5 Megawatt Turbine Generator
【24h】

Vibration Analysis and Compromising Balance of 4.5 Megawatt Turbine Generator

机译:4.5兆瓦汽轮机发生器的振动分析和损害平衡

获取原文

摘要

A problem with vibration above the acceptance criteria (2.0 mils pk - pk) for a new installation occurred during the initial operation of a turbine generator. The unit vibration increased from less then 1.0 mil pk - pk displacement with the unit unexcited; to 4.66 mils pk - pk at 25percent load. This paper will deal with the analysis and balancing of a thermally induced imbalance in a small co - generation plant. The author will generally describe what needs to be done when balancing a thermal problem to acceptable vibration limits. The static couple method of balancing will be used along with plots of the thermal movement. The author describes in detail the test plan along with the data analysis.
机译:在涡轮发电机的初始操作期间发生在接受标准(2.0密耳PK-PK)上方的振动问题。单位振动从较少的1.0密耳PK - PK位移增加,与本机未经发出;到4.66密耳PK - PK在25平台负载。本文将处理在小型生成植物中热诱导的不平衡的分析和平衡。作者通常会描述在平衡热问题到可接受的振动限制时需要做的事情。静态耦合的平衡方法将与热运动的图一起使用。作者详细描述了测试计划以及数据分析。