首页> 外文会议>Annual International Conference of the IEEE Engineering in Medicine and Biology Society >Analysis and comparison of the signal difference to noise ratio (SDNR), signal difference (SD), and the signal to noise ratio (SNR): evaluating the suitability of the SD and SDNR as MRI quality control parameters
【24h】

Analysis and comparison of the signal difference to noise ratio (SDNR), signal difference (SD), and the signal to noise ratio (SNR): evaluating the suitability of the SD and SDNR as MRI quality control parameters

机译:噪声比(SDNR),信号差(SD)和信噪比(SNR)信号差的分析和比较:评估SD和SDNR作为MRI质量控制参数的适用性

获取原文

摘要

The SDNR value is a display independent parameter that quantitatively measures the contrast-generating ability of a MR protocol. The intent of this research effort was to investigate the performance and suitability of the SDNR and SD measurements as possible MRI quality control parameters to augment the SNR currently employed, Six clinical MRI units were surveyed daily for a 5-week period. A quality control phantom was imaged at the start of each day and the SDNR, SD, and SNR values were calculated and recorded. In addition to daily measurements, performance testing investigated the following seven factors; (1) slice thickness, (2) TR, (3) TE, (4) FOV, (5) NEX, (6) flip angle, and (7) RF nonuniformity. The SDNR performance was similar to SNR performance in the tests conducted. The SD performance was similar to both the SNR and SDNR; however, the sensitivity of the SD measurement was greater in the RF non-uniformity performance tests. Testing results confirm the capability of the SDNR parameter to be used as a QC indicator. Based on the results of the RF nonuniformity test there is a notable and significant difference in sensitivity of the SD and SDNR parameters when compared to the SNR and SDNR measurements. The study results indicate that the SDNR and SD measures could be used to augment the SNR quality control parameter, thereby providing additional quality control capability. Both parameters are easily automated and can be incorporated to augment existing quality control parameters.
机译:SDNR值是显示独立参数,可定量测量MR协议的对比产生能力。这项研究努力的目的是调查SDNR和SD测量的性能和适合性,以尽可能的MRI质量控制参数增加目前所采用的SNR,每日调查六个临床MRI单位为期5周。在每天的开始时对质量控制幻像进行成像,并计算并记录SDNR,SD和SNR值。除日常测量外,性能测试还调查了以下七种因素; (1)切片厚度,(2)Tr,(3)Te,(4)FoV,(5)Nex,(6)翻转角,(7)rf不均匀性。 SDNR性能类似于进行测试中的SNR性能。 SD性能类似于SNR和SDNR;然而,在RF非均匀性性能测试中,SD测量的灵敏度更大。测试结果证实了SDNR参数用作QC指示灯的能力。基于RF不均匀性测试的结果,与SNR和SDNR测量相比,SD和SDNR参数的灵敏度有一个显着且显着的差异。研究结果表明,SDNR和SD措施可用于增强SNR质量控制参数,从而提供额外的质量控制能力。这两个参数都很容易自动化,可以合并到增强现有的质量控制参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号