首页> 外文会议>International cryogenic engineering conference >Cryogenic experiences and test results of the Wendelstein 7-x (W7-X) demo coil test in TOSKA
【24h】

Cryogenic experiences and test results of the Wendelstein 7-x (W7-X) demo coil test in TOSKA

机译:韦德斯坦7-X(W7-X)演示在TOSKA中的低温体验和测试结果

获取原文

摘要

The superconducting magnet system of the world largest stellarator experiment W7-X consists of 50 nonplanar and 20 planar coils. A first nonplanar W7-X DEMO coil was tested 1999 in TOSKA in a first combined test of two superconducting coils in this facility. After cool down, the W7-X coil was operated as single coil up to 19.8 kA conductor current at 3.8 K. In combined mode, the design values of 14 kA in the LCT coil and 14.7 kA in the W7-X coil were realized under stable conditions and, in extended mode, the coils were tested with 14 kA in LCT and up to 16.7 kA in W7-X. Cryogenic test results will be presented hereafter.
机译:世界上最大的螺栓实验W7-X的超导磁体系统由50个非平面和20个平面线圈组成。在该设施中的两个超导线圈的第一次组合测试中,在TOSKA中测试了第一个非平面W7-X演示线圈。在冷却后,W7-X线圈以3.8k为3.8k的单线线圈操作,在3.8k中,在组合模式下,在LCT线圈中的14ka的设计值和W7-x线圈中的14.7ka稳定的条件,并且在扩展模式下,用14kA在LCT中测试线圈,W7-x中最多16.7ka。以下将提出低温测试结果。