In this paper, we present the theoretical analysis and predictions of these optimum positions of the vapour cooled shields, in MLI structure of a 100 litre capacity superinsulated demountable type liquid helium test cryostat, following the procedures of Bejan and Qingfu Li et al. The vapour cooled shields were cooled by the evaporating helium gas by connecting them at appropriate positions of the stainless steel neck tube, whose temperature profile is also predicted for the given evaporation rate. The paper presents the details of the experimental system along with the instrumentation for temperature measurements. The experimental results at steady state conditions such as evaporation rate of the cryostat, temperature profile of the neck tube and the superinsulation are presented.
机译:在本文中,我们介绍了蒸汽冷却屏蔽的这些最佳位置的理论分析和预测,在100升容量超出缺失型液氦氦试验率的MLI结构中,按照Bejan和Qingfu Li等人的程序。通过在不锈钢颈管的适当位置连接它们通过将蒸发氦气冷却蒸汽冷却屏蔽,其温度曲线也预测给定的蒸发速率。本文介绍了实验系统的细节以及温度测量的仪器。提出了稳态条件下的实验结果,例如低温恒温器的蒸发速率,颈管的温度曲线和超然。