The Off-Design behaviro of the two Hybrid Gas-Steam Combined Plants equipped with Pressurized Fluidized Bed Combustors designed in Part one of the present work has been analyzed. Off-Design behavior has been investigated by varying the following quantities: i) Base Line Gas Turbine IGV setting; ii) Base Line Gas Turbine inlet temperature, iii) Fluidized Bed Heat Exchanger bed height. Results show the capability of both plants to operate efficiently at reduced load.
机译:已经分析了配备有压力化流化床燃烧器的两个混合气体蒸汽组合设备的偏移行为已经分析了在本作一部分的一部分中。已经通过改变以下数量来调查了非设计行为:i)基线燃气轮机IGV设置; ii)基线燃气轮机入口温度,III)流化床热交换器床高度。结果表明,两种植物在减少负荷下有效地运行的能力。