首页> 外文会议>Joint Canada-Japan Workshop on Composites >Reinforced concrete Columns Confirned by FRP Grids
【24h】

Reinforced concrete Columns Confirned by FRP Grids

机译:FRP网格限制的钢筋混凝土柱

获取原文

摘要

Experimental investigation was carried out to verify the use of fiber reinfroced polymer (FRP) grids as transverse reinforment. The emphasis was placed on concrete confinement and seismic performance. Large-scale column specimens were tested under simulated seismic loading. The column reinforcement cages consisted of ordinary steel reinforcement as longitudinal bars and fiber reinforced polymer grids as transverse reinforcement. Grid spacing, grid pattern and the volumetric ratio of grid reinforcement, as well as the level of axial load were considered as test parameters. The results indicate improved deformability of columns when confined by properly designed grids. The grids provided easy cage assembly, savings in materials, and improved performance, while eliminating the congestion of column cage. Columns reinforced with fiber reinforced polymer grids developed at least 3
机译:进行了实验研究,以验证纤维再掺杂聚合物(FRP)网格作为横向增强。重点是混凝土限制和地震性能。在模拟地震载荷下测试大规模柱样品。柱加固笼包括普通钢筋作为纵向棒和纤维增强聚合物网格作为横向加强。网格间距,网格图案和电网增强件的体积比以及轴向载荷水平被认为是试验参数。结果表明,当由适当设计的网格限制时,柱的可变形性。网格提供易于笼组装,节省材料,提高性能,同时消除了柱笼的拥塞。用纤维增强聚合物网格加固的柱至少产生3

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号