首页> 外文会议>International Power Electronics and Motion Control Conference >Flux Balance Assurance in Output Transformers of Sine-Wave Inverters Using DC Autonulling Control Principle
【24h】

Flux Balance Assurance in Output Transformers of Sine-Wave Inverters Using DC Autonulling Control Principle

机译:使用直流自动抑制控制原理的正弦波逆变器输出变压器的助焊剂平衡保证

获取原文

摘要

A new approach for flux imbalance prevention is proposed in this paper. The basic idea is to suppress DC component of the transformer primary voltage using the closed control loop around the hybrid amplifier with the first order low-pass filter and the integrator in the feedback path. The operation of proposed scheme is analyzed in detail analytically and by means of computer simulations. Experimental results are in accordance with simulations and confirm the suitability of the cost effective solution.
机译:本文提出了一种新的助焊剂不平衡预防方法。基本思想是使用混合放大器周围的闭合控制环路抑制变压器初级电压的直流分量,其中一阶低通滤波器和反馈路径中的积分器。分析和通过计算机模拟详细分析所提出的方案的操作。实验结果符合模拟,并确认了成本效益的解决方案的适用性。