Inductive power transmission system with stabilized output voltage using local primary-and secondary-side control

机译:稳定输出电压的电感电力传输系统使用本地初级和次级侧控制

获取原文

摘要

In this paper, a primary and secondary series compensated inductive power transmission system with primary-side zero phase angle control and a loss-free clamp (LFC) circuit on the secondary-side is described. The effects of non-synchronous tuning are analyzed and intendet detuning is proposed to guarantee controllability. The functional principle of the LFC circuit, which is required for output voltage stabilization over a wide load range and varying magnetic coupling, is explained. Finally, theoretical results are verified experimentally.
机译:在本文中,描述了具有初级侧向零相位角控制的主要和次级串联补偿电感电力传输系统和次级侧的无损耗钳位(LFC)电路。分析了非同步调谐的影响,提出了不可控制的不可控制性。解释了LFC电路的功能原理,其在宽负载范围内输出电压稳定和变化的磁耦合所需的电路。最后,经过实验验证理论结果。

著录项