Thermal vacuum qualification testing for the International Space Station heat rejection system radiators

机译:国际空间站散热系统散热器的热真空资格测试

获取原文

摘要

The Heat Rejection Subsystem (HRS) Radiators Orbital Replaceable Unit (ORU) for the International Space Station has undergone thermal vacuum qualification testing at NASA Plum Brook Station, Space Power Facility in Ohio. The testing was conducted from December 1996 through January 1997 and October 4 through 18, 1997. This testing included confirmation of the heater control assembly (HCA) and heater performance that was initially tested during December 1996 through January 1997. Deployment system functional operations were tested for both hot and cold conditions using both the Integrated Motor Control Assembly (IMCA) and the Extravehicular Activity (EVA) drive.
机译:国际空间站的散热子系统(HRS)散热器轨道可更换单元(ORU)在俄亥俄州的空间电力设施中经历了热真空资格测试。该测试是从1996年12月到1997年1月和10月4日至1997年1月18日进行的。该测试包括在1996年12月至1997年1月期间最初测试的加热器控制组件(HCA)和加热器性能。部署系统功能运营进行了测试对于使用集成电机控制组件(IMCA)和套管活动(EVA)驱动器的热和冷条件。